远程控制超声扫描的远端操纵系统()
分享到:

机械与电子[ISSN:1001-2257/CN:52-1052/TH]

卷:
期数:
2020年03期
页码:
48-52
栏目:
自动控制与检测
出版日期:
2020-03-24

文章信息/Info

Title:
Manipulating System for Remote -control Ultrasonic Scanning
文章编号:
1001- 2257(2020)03- 0048- 05
作者:
沈 运谢荣理赵艳娜付 庄王 尧张 俊费 健张铁锋
1.上海交通大学机械系统与振动国家重点实验室,上海 200240;
2.上海交通大学医学院附属瑞金医院,上海 200025;
3.上海市瑞金康复医院,上海 200023;
4.上海市宝山区大场医院,上海 200436
Author(s):
SHENYunXIERongliZHAOYannaFUZhuangWANGYaoZHANGJunFEIJianZHANGTiefeng
1.StateKeyLaboratoryofMechanicalSystemandVibration,ShanghaiJiaoTongUniversity,Shanghai200240,China;
2.RuijinHospitalAffiliatedtoShanghaiJiaoTongUniversity,Shanghai200025,China;
3.ShanghaiRuijinRehabilitation
Hospital,Shanghai200023,China;
4.BaoshanDistrictDachangHospital,Shanghai200436,China
关键词:
远程超声扫描远端操纵系统阻抗控制人机协作
Keywords:
remoteultrasonicscanningremotemanipulatingsystemimpedancecontrollinghumanmachinecollaboration
分类号:
TP275
文献标志码:
A
摘要:
针对远程超声扫描,研制了一种远端操纵系统,并实现了超声探头的人机协作控制。探头控制中利用远端操纵系统网传信号实时复现远端操作员的扫描动作,并在此基础上利用阻抗控制方式自动控制探头对皮肤的压力。实验结果表明:近端超声探头的位置误差和姿态误差分别保持在±2.0mm和±1.5°以内,能较好地复现操作员的扫描动作;探头压力跟踪误差稳定在±0.5N 的范围内,不但能将操作员的扫描手感真实地
施加到皮肤上来提升其临场感,而且为进一步提高超声图像的质量,增强超声扫描的安全性提供了参考。
Abstract:
A remote manipulating system was developed to achieve human-machine collaboration controlling in remote ultrasonic probe. The scanning action of a remote operator was reproduced by the signals collected from the remote manipulating system in real time, then the skin’s pressure generated from the probe was controlled automatically through an impedance controlled method. The experimental results show that the scanning action can be relatively reproduced with the position error and attitude error of the probe kept within ±2.0 mm and ±1.5? respectively in the near-end ultrasonic probe. Moreover, the tracking error of probe pressure is stable within ±0.5 N, which can not only enhance the operator’s scanning feeling to the skin, but also provide references to improve the quality of ultrasonic images and scanning safety.

参考文献/References:

[1] 朱桂林.全数字B超诊断仪波束合成技术的研究[D].重庆:重庆理工大学,2016.

[2] 魏汝峰,边希增.高频超声弹性成像与超声造影在甲状腺结节良恶性鉴别中的应用价值[J].临床医学研究与实践,2019,4(1):134- 135.
[3] MONFAREDIR,WILSON E,AZIZIKOUTENAEI B,etal.Robot assistedultrasoundimaging:overviewanddevelopmentofaparallelteleroboticsystem
[J].MinimallyInvasiveTherapyandAlliedTechnologies,2015,24(1):54- 62.
[4] GEORGESCU M,SACCCOMANDIA,BAUDRONB,etal.RemotesonographyinroutineclinicalpracticebetweentwoisolatedmedicalcentersandtheUniversityHospitalusingaroboticarm:a1 yearstudy[J].Telemedicineande Health,2016,22(4):276- 281.
[5] BOMANK,OLOFSSON M,BERGGRENP,etal.Robot assistedremoteechocardiographicexaminationandteleconsultation:arandomizedcomparisonoftimetodiagnosiswithstandardofcarereferralapproach[J].JACC:CardiovascularImaging,2014,7(8):799- 803.
[6] SENGUPTA PP,NARULA N,MODESTO K,etal.Feasibilityofintercityandtrans Atlanticteleroboticremoteultrasound:assessmentfacilitatedbyanondedicatedbandwidthconnection[J].JACC:CardiovascularImaging,2014,7(8):804- 809.
[7] SEOJ,CHOJ,WOO H,etal.Developmentofprototypesystemforrobot assistedultrasounddiagnosis[C]//201515thInternationalConferenceonControl,AutomationandSystems(ICCAS).NewYork:IEEE,2015:1285- 1288.
[8] ADAMSSJ,BURBRIDGEBE,BADEAA,etal.Acrossovercomparisonofstandardandteleroboticapproachestoprenatalsonography[J].JournalofUltrasoundinMedicine,2018,37(11):2603- 2612.
[9] 远程超声诊断系统[J].工业设计,2019(6):9.
[10] 刘金鑫,靳泽宇,李雯雯,等.5G远程医疗的探索与实践[J].电信工程技术与标准化,2019,32(6):83- 86.

备注/Memo

备注/Memo:
收稿日期:2019- 11- 11
基金项目:国 家 自 然 科 学 基 金 面 上 项 目 (61973210);上 海 市 黄 浦 区 科 研 新 项 目 (HKQ201810);上 海 市 科 学 技 术 委 员 会 项 目(17441901000);医工交叉项目(YG2019ZDA17,ZH2018QNB23);上海市卫计委项目(201640230,20144Y0084)
作者简介:沈 运 (1995-),男,上海人,硕士研究生,研究方向为医疗机器人;谢荣理 (1990-),男,上海人,住院医师,研究方向为机器人的临床应用;赵艳娜 (1985-),女,上海人,主治医师,研究方向为超声诊断及介入治疗;付 庄 (1972-),男,山东招远人,教授,研究方向为特种机器人与控制系统,通信作者;王 尧 (1988-),男,山西平遥人,博士,博士后,研究方向为医
疗/穿刺手术机器人。
更新日期/Last Update: 2020-04-21